FINA SUCTION controllers have been developed especially for the fields of bronchoaspiration, bronchoaspiration in pediatrics, drainage and thoracic drainage. Thanks to their high-performance, finely adjustable suction, the durable systems are ideal for constant use in hospitals and specialized medical practices.

The FINA SUCTION controllers by Maquet bring together elegant appearance, robust construction, finest workmanship, secure handling and an economical overflow protection system. FINA SUCTION has been awarded the red dot design prize, yet is part of wide product portfolio that fulfils all medical specifications.

Broad Product Portfolio

The powerful, finely adjustable FINA SUCTION controllers are available for a modern, application-specific gas supply for the fields of:

Bronchoaspiration and Surgical Aspiration

  • FINA AIR B 800
  • FINA VAC B 800

Bronchoaspiration in Pediatrics

  • FINA AIR P 350
  • FINA VAC P 350

Drainage

  • FINA AIR D 150
  • FINA VAC D 150

Thoracic Drainage

  • FINA AIR T 50
  • FINA VAC T 50

State-of-the-Art in Every Aspect

The FINA Suction controllers for compressed air and vacuum offer many important clinical features. Modular Overflow Protection. FINA SUCTION controllers offer the range of options needed in today's clinical area.

Basic Equipment for Disposable Systems

The cost saving basic version of FINA SUCTION controllers can be used in cases where hospitals or specialized medical practices use disposable systems with hydrophobic filters.

Mechanical Overflow Protection

A special mechanical overflow protection with integrated float can be directly mounted on the FINA SUCTION device. In case the overflow jar is filled, the float automatically stops the suction process, preventing oversuction.

Hydrophobic Bacterial and Viral Filter

A hydrophobic filter at the tube offers nearly 100% protection against oversuction and bacterial and viral contamination.

Distinctive Gauge

Modern hospitals and specialized practices need innovative, flexible and state-of-the-art technology. The new frontal gauge for the FINA SUCTION controllers offers crucial advantages:

  • Easy to Read- 360 degree rotation allows the gauge to be read from any position on the patient side 
  • Excellent Ease of Operation- easy removal for easy cleaning 
  • Maximum safety- secure bayonet lock and mechanical coding of the gauge prevent the wrong combination of housing and gauge

FINA AIR B 800 and FINA VAC B 800

These controllers are especially designed for the fields of bronchoaspiration and surgical aspiration. They are best suited for the needs of OR, intensive care and specialized medical practices. FINA AIR B 800 and FINA VAC B 800 quickly and quietly suck away large amounts of septic fluid, blood and other liquids that occur.

FINA AIR B 800

  • High flow rate of at least 30 l/min
  • High, adjustable vacuum of more than -80 kPa
  • Integrated safety valve on the patient side, according to European standards, to avoid overpressure on the patient
  • Shut-off valve for comfortably opening and closing the vacuum supply
  • Additional advantage: the propellant air consumption is reduced by 20 percent and minimizes the operating costs while offering unrivaled high performance

FINA VAC B 800

  • Extremely high flow rate of at least 50 l/min
  • High vacuum of up to -80 kPa
  • Shut-off valve for comfortably opening and closing the vacuum supply
  • Reduction of the vacuum at the patient side by membrane regulation is possible at any time

Top-View Gauge

In addition to the frontal gauge, FINA AIR B 800 and FINA VAC B 800 are also available with a top-view gauge.

FINA Mobile Suction Unit

The combination of intensive care trolley and FINA AIR B 800 or FINA VAC B 800 is the perfect mobile surgical aspirator to be independent of the power supply in hospitals and specialized medical practices. It is directly connected to the central gas supply system.

  • Optimally fitted with FINA AIR B 800 or FINA VAC B 800
  • Stainless steel trolley with two equipment rails 25 x 10 mm and smooth running anti-static castors (two of them with brakes)
  • Flexible modular overflow protection system
  • Comfortable top-view gauge
  • Autoclavable mechanical overflow protection system
  • Individual application sets for surgical aspiration
  • NIST connection for connection tubes

FINA Suction Unit Compact

The practical combination of portable bearing frame and FINA AIR B 800 or FINA VAC B 800 is best suited for the intensive care. In combination with the various application sets for septic fluid aspiration the FINA Suction Unit Compact offers a powerful, finely adjustable bronchoaspiration.

  • Optimally fitted with FINA AIR B 800 or FINA VAC B 800
  • Portable bearing frame
  • Flexible modular overflow protection system
  • Comfortable top-view gauge
  • Individual application sets for septic fluid aspiration
  • NIST connection for connection tubes

FINA AIR P 350 and FINA VAC P 350

These controllers have especially been developed for the needs of pediatric and neonatal bronchoaspiration (blood, septic fluid and any other liquids). With reduced vacuum, a corresponding precision adjustment and a finely calibrated pediatric gauge, both devices are particularly child-friendly – also in permanent operation.

FINA AIR P 350

  • Low flow rate of at least 14 l/min
  • Medium-range vacuum of -35 kPa max
  • Integrated restriction of the compressed air by reduced diameter is the basis for precision adjustment of the vacuum and thus certain that no damage is caused to infants or neonates during bronchoaspiration
  • Integrated safety valve on the patient side according to European standards to avoid overpressure on the patient
  • Special pediatric calibration of the frontal gauge
  • Shut-off valve for comfortably opening and closing the vacuum supply

FINA VAC P 350

  • Low flow rate of 18 l/min
  • Medium-range vacuum of -35 kPa max
  • Special pediatric calibration of the frontal gauge
  • Shut-off valve for comfortably opening and closing the vacuum supply
  • Reduction of the vacuum at the patient side by membrane regulation is possible at any time

FINA AIR D 150 and FINA VAC D 150

Every kilopascal counts in the postoperative aspiration of wound exudates, septic fluid, air and serous fluids. Thanks to their special technical design and the finely adjustable output, the FINA AIR D 150 and FINA VAC D 150 are designed for the particular requirements of wound drainage. Among other things, they are best suited for silent, constant operation.

FINA AIR D 150

  • Low flow rate of at least 8 l/min
  • Low vacuum of up to -13 kPa
  • No integrated shut-off valve to ensure that the risk to the patient is kept as low as possible in the case of especially sensitive drainage
  • Integrated safety valve on the patient side, according to European standards, to avoid overpressure on the patient
  • Finely calibrated gauge scale

FINA VAC D 150

  • Low flow rate of at least 13.5 l/min
  • Low vacuum of up to -13 kPa
  • Reduction of the vacuum at the patient side by membrane regulation is possible at any time
  • No integrated shut-off valve to ensure that the risk to the patient is kept as low as possible in the case of especially sensitive drainage
  • Finely calibrated gauge scale

FINA AIR T 50 and FINA VAC T 50

With their particularly low flow rate and extremely low vacuum, FINA AIR T 50 and FINA VAC T 50 support fine vacuum adjustment of less than -5 kPa. This makes them perfect for reliable thoracic drainage in constant operation in hospitals and specialized medical practices.

FINA AIR T 50

  • Low flow rate of at least 15 l/min
  • Extremely low vacuum of up to -5 kPa
  • Finely calibrated gauge scale
  • Integrated patient-side safety valve, according to European standards, to protect the patient in the event of overpressure
  • No integrated shut-off valve to ensure that the risk to the patient is kept as low as possible in the case of especially sensitive thoracic drainage
  • Extremely economical compressed air consumption

FINA VAC T 50

  • Low flow rate of 16 l/min
  • Extremely low vacuum of up to -5 kPa
  • Finely calibrated gauge scale
  • Integrated patient-side safety valve according to European standards to protect the patient in the event of overpressure
    No integrated shut-off valve to ensure that the risk to the patient is kept as low as possible in the case of especially sensitive thoracic drainage
  • Reduction of the vacuum at the patient side by membrane regulation is possible at any time

Great number of connection forms

According to the individual requirements of hospitals or specialized medical practices, the FINA SUCTION controllers can be integrated into every central gas supply system.

  • Direct extraction from CSS: MEDAP, DIN and several other country standards
  • Mounting to equipment rail 25 x 10 mm (German standard) - with NIST connection
  • Equipment mount for connection to other equipment rails - with NIST connection

Connection tubes with gas probes

For FINA suction controllers for equipment rail and equipment mounts, a complete range of connection tubes is available in several lengths, in different color coding and with a wide range of different gas probes. For more information please look at Gas probes, connection tubes.

How to order

To place an order or learn more about any of the Maquet products, related accessories, or therapeutic solutions, please contact your local sales representative. 

Informação relacionada